Measure Height to the Top of the Opening #
This Variant is for windows where the top of the opening is 10 feet or more above the finished floor. That is a working-height measurement. The window itself does not have to be 10 feet tall. A shorter window installed high on a wall can need the same access.
Use How to Case a Window for the picture-frame casing layout, cuts and normal fastening. The main change here is keeping one end of the head casing movable while you glue and secure the opposite top corner. Then return to finish the tacked corner.
Which guide do I need?
- One window with four mitered corners: How to Case a Window
- Opening tops 90 to 119 inches above the finished floor: Window Casing for Medium-Tall Windows (90″ to 119″)
- Top of the opening 10 feet or more above the finished floor: this guide
- Two or more windows side by side: How to Case Ganged Windows
Plan Access and Stock #
- Ladder: Choose it for the actual reach and working position, within its marked standing-height and load limits. Reposition it for each corner. The 10-foot opening-top height does not establish a universal ladder size.
- Actual casing lengths: Measure the opening and the pieces you need. A head 10 feet above the floor does not make the side casings 10 feet long.
- Saw and stock support: Use the miter saw and support long pieces level with its table so they do not droop during the cut.
- Casing nailer and wood glue: Use the established casing fastening method in the Standard guide. See Nail Guns and Air for the tool reference.
Buy stock long enough for each full piece. Casing splices are rare, generally needed only when a run exceeds the longest available stock, about 16 feet. When a length splice is needed, use matching 45-degree cuts. Do not turn an ordinary stock-length shortage into a routine splice.
Install the Head Casing One End at a Time #
Step 1: Inspect and Mark the Reveal #
Inspect the jamb, the frame edge the casing meets, at the full opening. Check that it sits flush with the wall. Correct a jamb that stands proud of the drywall before casing.
Mark the reveal, the strip of jamb left showing, at 3/16 inch. Follow that line when fitting the casing. Use the ladder for the parts you cannot reach from the floor; the amount of the opening above reach depends on its actual position.
Step 2: Measure and Cut the Pieces #
Measure the head and each side from the actual reveal marks. Follow the Standard guide for the miter cuts and fitting. Support any long stock during cutting and handling. The bottom casing uses the same basic technique; its working height depends on where the bottom of this opening is located.
Step 3: Temporarily Tack One End of the Head #
Position the head casing at the reveal. Put a temporary tack through the wall side of one end, over the drywall, leaving that end free from the jamb. It must still be able to move a little while you fit the opposite corner. Do not fully nail off both ends before the top miters fit.
Keep the head controlled as you position it. Check the temporary hold before moving to the opposite end. If you cannot keep the stock secure and work safely, get a helper and change the setup. The tack is a positioning aid, not a substitute for reliable support.

Step 4: Glue and Secure the Opposite Top Corner #
Reposition the ladder at the opposite end of the head. Fit that side-casing piece to the head miter and the reveal marks. Apply wood glue liberally to both miter faces, pull the joint tight and hold it until the glue grabs. Secure that side and the head at this corner using the Standard casing method. Glue holds the miter; do not cross-nail it.
Step 5: Return to the Tacked End and Finish #
Return to the temporarily tacked end. Use the movement left there to fit the other side casing and close its top miter. Glue both faces, hold the joint tight and secure this corner. Finish the normal casing fastening after both top corners fit. Keep the casing aligned with the reveal as you work.
Complete the bottom casing using the Standard guide. Glue the joints, putty and sand the wood-to-wood joints, set proud brads below the surface, clean off glue and sweep up. Nail-hole filling, wall-edge caulk and painting remain the painter's work.
Ladder Setup for This Work #
Use the actual ladder according to its labels and instructions. OSHA's ladder guidance covers secure footing, climbing and permitted standing positions:
- Set the ladder on stable, level footing or secure it against displacement using its approved setup.
- For a stepladder, open it fully and use the standing steps permitted by its markings. Do not stand on its top or top step.
- Maintain three points of contact while climbing. Do not carry tools or stock that could make you lose balance.
- Climb down and move the ladder to the other corner instead of reaching across a wide opening. If the position will not let you work safely, change the access setup.
If you need a platform or scaffold, use equipment designed and set up for that purpose. Source: OSHA ladder guidance, pages 18 and 19, citing 29 CFR 1926.1053.
Check Before Leaving the Window #
- Both top miters are glued, closed tight and secured; neither corner was left as a temporary tack.
- The reveal stays consistent at 3/16 inch around the opening, with casing seated to the jamb and wall.
- Check each side for its actual full length. Working height does not establish the leg length.
- Wood-to-wood joints are finished, proud brads are set and glue is cleaned from the upper joints.
- The window opens, closes and locks as it did before casing.
Problems to Correct #
The Tacked End Will Not Move #
Check whether it was fastened to the jamb or nailed off too firmly before the opposite corner was fitted. Keep only the temporary wall-side hold needed for positioning while maintaining reliable support. Fit the top corners before completing the normal fastening.
A Top Miter Opens While You Work #
Support the piece, reopen the fastening that is pulling the joint out of position and refit it. Glue both miter faces and hold the joint tight before securing it. Do not rely on cross-nails or an assumed quick-setting adhesive to replace a fitted joint.
The Casing Will Not Sit Flat #
Inspect the stock and the jamb-to-wall fit before forcing the casing into place. Correct the fit using the Standard guide, and replace stock that will not give a clean result. The casing follows the jamb reveal; a long level is not the layout reference for this task.
Related Guides #
- How to Case a Window - Standard picture-frame casing process.
- Window Casing for Medium-Tall Windows (90 to 119 Inches) - The lower height range.
- How to Case Ganged Windows - Two or more windows side by side.
- Interior Window Frame for Tall Openings - Building the frame is a separate task from casing it.
Reference Photos #
The following photos show examples of this type of work completed in the field. These serve as visual references for quality standards, proper installation techniques, and finished results.
Showing 6 of 6 photos